CompTIA A+ Core 1 · 220-1201

Objective 5.2: Troubleshoot drive and RAID issues

Try it now: 8 quick questions on this objective, no account needed.

Objective 5.2 · Drive and RAID problems

1 / 8
Quick scenario

A technician is setting up a RAID 10 array. What is the minimum number of drives required?

Practice questions for A+ Core 1 objective 5.2, “Troubleshoot drive and RAID issues.” Every question is original, written to the 220-1201 exam objectives, and comes with a full explanation — answer them below to see instant grading.

This objective sits in Domain 5.0: Hardware and Network Troubleshooting, which is about 28% of the exam — so mastering it moves your readiness score meaningfully.

More 5.2 practice questions

Objective 5.2 · practice questions

1 / 5
Exam style

A workstation's storage LED is continuously lit without any user activity. What does this indicate?

All 5 questions, with answers
  1. 1.A workstation's storage LED is continuously lit without any user activity. What does this indicate?

    • A.The drive is in a power-saving sleep mode
    • B.The system is experiencing high disk activity, possibly due to paging or malware
    • C.The drive firmware is updating automatically
    • D.The SATA cable is loose

    Answer: B. The system is experiencing high disk activity, possibly due to paging or malware. A continuously lit drive activity LED during periods of expected inactivity suggests heavy background disk activity, which can be caused by Windows indexing, updates, excessive paging due to low RAM, or malware. Drive sleep mode would turn off the LED, not keep it lit. Persistent disk activity with no visible user cause warrants investigation of background processes and potential malware scanning.

  2. 2.A technician connects a replacement hard drive and hears a loud clicking noise when the drive is powered on. What does this indicate?

    • A.Normal drive calibration during first power-on
    • B.The drive has a failing read/write head — a condition known as the "click of death"
    • C.The SATA cable is not properly connected
    • D.The drive is performing a SMART self-test

    Answer: B. The drive has a failing read/write head — a condition known as the "click of death". A repetitive clicking sound from a hard drive (called the "click of death") indicates that the read/write head is failing to find its home position, which is a sign of imminent or active mechanical failure. Normal drive calibration is nearly silent. If a drive clicks, power it off immediately — continued operation with a clicking drive risks complete data loss.

  3. 3.A technician is setting up a RAID array for a small business requiring both redundancy and improved read performance with at least three drives. Which RAID level BEST meets these requirements?

    • A.RAID 0
    • B.RAID 1
    • C.RAID 5
    • D.RAID 10

    Answer: C. RAID 5. RAID 5 provides both redundancy (via distributed parity) and improved read performance using a minimum of three drives, making it ideal for the described scenario. RAID 0 provides no redundancy, and RAID 1 only mirrors two drives without performance gains. RAID 5 balances capacity, performance, and fault tolerance for small business storage environments.

  4. 4.After replacing a failed drive in a RAID 5 array, the rebuild process takes over 12 hours and the array remains in a degraded state during this time. What is the PRIMARY risk during this rebuild period?

    • A.The remaining drives will be overloaded and fail from heat
    • B.A second drive failure would result in complete data loss
    • C.The RAID controller will corrupt the rebuild
    • D.Users cannot access data while the rebuild is in progress

    Answer: B. A second drive failure would result in complete data loss. During a RAID 5 rebuild, the array is in a degraded state with no redundancy; if any remaining drive fails before the rebuild completes, all data is permanently lost. Users can typically still access data during a RAID 5 rebuild in degraded mode, though at reduced performance. The longer the rebuild takes, the greater the window of vulnerability — large RAID 5 arrays with big drives have increasingly long rebuild times, which is why RAID 6 is preferred for high-capacity arrays.

  5. 5.A workstation running Windows shows a drive in Disk Management as "Foreign." What does this indicate?

    • A.The drive is encrypted with a third-party tool
    • B.The drive is a dynamic disk that was initialized on a different Windows computer
    • C.The drive has an incompatible file system
    • D.The drive has a hardware failure

    Answer: B. The drive is a dynamic disk that was initialized on a different Windows computer. A "Foreign" disk in Windows Disk Management indicates a dynamic disk whose configuration database was created on a different Windows system — importing it restores access to its volumes. A drive with an incompatible file system shows as having a raw or unknown file system, not "Foreign." Dynamic disks track configuration in a hidden partition; when moved to a new system, Windows must import the disk to read that configuration.

Learn 5.2 and every other objective

Your A+ Core 1 path walks the whole exam in short stops, one objective at a time, and maps where you stand as you go.

Start my A+ Core 1 path

No account needed to start.

More objectives in Domain 5.0

← All A+ Core 1 220-1201 objectives